The pinetime smartwatch does not have a serial port.
A way around this is to use a Segger Jlink debug-probe and enable logging and shell over RTT:
in prj.cfg:
CONFIG_LOG=y
CONFIG_USE_SEGGER_RTT=y
CONFIG_SHELL=y
CONFIG_SHELL_BACKEND_RTT=y
start the debugger :
west debug
and enter : continue
This starts up in the background "Segger Jlink Processes"
NOTE: What happens when you type : west debug? You could type this on the command prompt.
(this start the server)
JLinkGDBServer -select usb -port 2331 -if swd -speed 4000 -device nRF52832_xxAA -silent -singlerun
(this starts the debug session)
~/zephyr-sdk/arm-zephyr-eabi/bin/arm-zephyr-eabi-gdb /root/zephyrproject/app/build/zephyr/zephyr.elf -ex target :2331 -ex halt -ex reset -ex load
telnet 127.0.0.1 19021 (putty on linux) start the rtt console and shows the debug-log
The ds-D6 smartwatch has a serial port.
The blackmagicprobe can lauch a debugger : west debug --runnerblackmagicprobe.
The probe has a serial port /dev/ttyACM1 (linux : minicom -b 115200 -D /dev/ttyACM1)
If you do not have a Segger debug probe nor a serial port, you can put a value in memory at a fixed location.
With openocd you can peek at this memory location.
If you own a raspberry pi or an orange pi, you can use the GPIO header.
Another cheap option is an stm32 debug probe.
NOTE: #define MY_REGISTER (*(volatile uint8_t*)0x2000F000)
in the program you can set values: MY_REGISTER=1; MY_REGISTER=8;
this way you know till where the code executes
#telnet 127.0.0.1 4444
programming
once your telnet sessions started:
Trying 127.0.0.1...
Connected to 127.0.0.1.
Escape character is '^]'.
Open On-Chip Debugger
>mdw 0x2000F000 0x1
the last byte shows the value of your program trace value